Dnr- Dept Of Natural Resources - OH
Clay Tiles/ Exterior Cladding
Punderson State Park Lodge Clay Roof Tiles
Bid Close Date:
Government bid alerts, regional filters, and fast access to documents
Clay Tiles/ Exterior Cladding
Punderson State Park Lodge Clay Roof Tiles
Bid Close Date:
Mobile Air Quality Monitoring Equipment Shelter
Bid Close Date:
Lot 1: Description: Mobile 14' L x 8' W x 8' H Air Quality Monitoring Equipment Shelter Specifications: Dimensions: 14' L x 8' W x 8' H Standard aluminum base frame. Pre- finished metal exterior cladding with aluminum trim, gray, tan, or ivory color. Fiberglass Reinforced interior cladding. Commercial grade tile or vinyl flooring slip resistant. Interior walls, white in color. Rubber Membrane Roof, slip resistant, no color preference. Roof exterior shall be designed to mount equipment & support personnel. Insulation in walls, ceiling and floor R25 Equivalent, must meet or exceed. 2018 Kentucky Building Code requirements. Insulated metal access door, 36" W Includes: Hydraulic door closer, weather stripping, door drip, door threshold, commercial type handle with Mechanical Key- less lock. Metal vertical ladder installed on outside of shelter allows roof access. shelter. Aluminum roof area railing system. System is removable for ease of transport. Must meet OSHA specifications. 8 Foot work bench along interior wall. Tie Down points and hardware must be included, exterior. Sidewall brackets that will work with standard EKTO shelter lifting jacks. ( Jacks not required) 3x2 Aluminum Skid runners ( 2) design that will fit EKTO twin axle transport trailer Model # ****- TR2. 2 Roof Penetration inlets includes flange and cap installed. 1 wall penetration. Electrical System: Meets or exceeds NEC regulations 200A Electrical System, 120/240V. All circuits to be protected by circuit breakers. In addition to the HVAC power requirements, there shall be a minimum of nine ( 9) duplex outlets on the shelter interior, minimum one ( 1) exterior quad GFI outlet mounted for easy access from roof. Shelter main power entrance shall be via Meter Socket and Mast. Minimum two 48x2 bulb fluorescent light fixtures mounted to the ceiling. Environmental Control: The shelter interior must be temperature controlled ( 75 degrees Fahrenheit +/- 4 degrees Fahrenheit) at exterior temperatures of - 30 degrees Fahrenheit to 100 degrees Fahrenheit, by use of
Mobile Air Quality Monitoring Equipment Shelter
Bid Close Date:
Lot 1: Description: Mobile 14' L x 8' W x 8' H Air Quality Monitoring Equipment Shelter Specifications: Dimensions: 14' L x 8' W x 8' H Standard aluminum base frame. Pre- finished metal exterior cladding with aluminum trim, gray, tan, or ivory color. Fiberglass Reinforced interior cladding. Commercial grade tile or vinyl flooring slip resistant. Interior walls, white in color. Rubber Membrane Roof, slip resistant, no color preference. Roof exterior shall be designed to mount equipment & support personnel. Insulation in walls, ceiling and floor R25 Equivalent, must meet or exceed. 2018 Kentucky Building Code requirements. Insulated metal access door, 36" W Includes: Hydraulic door closer, weather stripping, door drip, door threshold, commercial type handle with Mechanical Key- less lock. Metal vertical ladder installed on outside of shelter allows roof access. shelter. Aluminum roof area railing system. System is removable for ease of transport. Must meet OSHA specifications. 8 Foot work bench along interior wall. Tie Down points and hardware must be included, exterior. Sidewall brackets that will work with standard EKTO shelter lifting jacks. ( Jacks not required) 3x2 Aluminum Skid runners ( 2) design that will fit EKTO twin axle transport trailer Model # ****- TR2. 2 Roof Penetration inlets includes flange and cap installed. 1 wall penetration. Electrical System: Meets or exceeds NEC regulations 200A Electrical System, 120/240V. All circuits to be protected by circuit breakers. In addition to the HVAC power requirements, there shall be a minimum of nine ( 9) duplex outlets on the shelter interior, minimum one ( 1) exterior quad GFI outlet mounted for easy access from roof. Shelter main power entrance shall be via Meter Socket and Mast. Minimum two 48x2 bulb fluorescent light fixtures mounted to the ceiling. Environmental Control: The shelter interior must be temperature controlled ( 75 degrees Fahrenheit +/- 4 degrees Fahrenheit) at exterior temperatures of - 30 degrees Fahrenheit to 100 degrees Fahrenheit, by use of
Add keywords for your products or services. Smart Search helps catch related opportunities beyond exact matches.
Use the 14-day free trial and get email alerts with documents or official posting links.
Adjust keywords, regions, email schedule and email style. Use map view and filters when you want to explore.
Very good and accurate information about the tenders: consistent and precise.
You see a lot of tenders; you get emails with the alerts.
I closed deals thanks to the information gathered by the search tool. There’s no need to research across multiple media outlets.
Excellent information. Just what I was looking for.
A very good platform.
Excellent platform to help promote and expand the reach of your work.
The idea of ​​using a keyword and sending the information by email is very good.
I consistently received notifications about bids within the specific segment I chose to monitor. The system simplifies processes that used to be complex, offering a navigation experience that is easy, fast, and modern.
Practicality, speed, trust, and credibility—that’s what the work conveys. The information is precise and sharply targeted.
The bids appear appropriately based on my interests.
I like the way they provide information with the greatest possible accuracy. I love that.
It is complete and optimal, it improves my time.
It encompasses all portals in one place.
Monitor opportunities across federal, state and local sources without checking them one by one.
Receive matching bids by email, then open documents or the official posting from one place.
Filter by region, method and value. Use favorites, notes and removals to keep only what matters.
Add what you sell, get scheduled alerts, open documents or the official page, and use filters by region and method.