Homeland Security, Department Of- U. S. Coast Guard- Base Kodiak( 00045)
Safety Railings
USCG Air Station Kodiak Mezzanine Structures - The purpose of amendment 1 is to provide responses to questions received by the due date listed in the solicitation. Those questions and responses can be found in the attachment. The due date for quotes is not extended. This is a
Mezzanine Structures Two ( 2) identical, separate structural steel mezzanine packages, each with an overall footprint of 34' x 28' ( approx. 952 sq. ft. ), designed for a uniform live load of 150 psf with a deflection limit of L/360, a 10' 6 clear height, and a 12' deck height. Each package includes one ( 1) straight, IBC compliant staircase with a top landing and safety handrails. Flooring system to be heavy duty, open metal bar grating. Support columns must be designed for shim adjustment. Safety guardrails compliant with OSHA standards ( 42 height, mid rail, toe boards) must be removable or sleeve mounted.